This PREDATOR® 4375 Watt Portable Generator is great for home backup in emergencies, powering tools at job sites and more. This PGMA compliant generator features a large fuel tank, GFCI outlets, and CO SECURE® carbon monoxide shutdown for safety. Read More
Choose Certification:EPA III
EPA IIICARB (California)
Which Generator Is Right For You?

Which Generator Is Right For You?

Answer a few questions and we'll help you find the perfect Generator for your needs.

Start Now

Product Details

The PREDATOR® 4375 Max Starting Watt, 3500 Running Watt Gas Powered Portable Generator is built with reliability and safety in mind. Powered by a dependable 212cc PREDATOR® gas engine, this generator is compact, lightweight, and provides power wherever it's needed. The integrated volt meter and fuel gauge make it easy to monitor output. The large gas tank means runtime up to 16 hours @ 50% load.

  • CO SECURE® technology automatically shuts down the generator for safety when harmful levels of carbon monoxide are detected
  • Powerful PREDATOR® 212cc engine easily powers RV air conditioners and other applications
  • Runtime up to 16 hours @ 50% load
  • Low oil indicator/low oil shutdown
  • Circuit breaker protection prevents accidental overload
  • Outlet covers protect against the elements and rugged working conditions
  • Recoil start
  • Includes (2) 120V GFCI protected 5-20R duplex outlets, (1) 120/240V L14-30R twist-lock outlet, (1) 12VDC
  • Complies with ANSI/PGMA G300-2018 standard

Important Information

  • Wheel kit sold separately. This item can only be shipped within the 48 contiguous states via Standard Ground Shipping. Oversized item: cannot be shipped to Alaska or Hawaii. In order to return this item for a refund or replacement, all fuel must first be drained.
Predator 4375 Watt Gas Powered Portable Generator with CO SECURE Technology EPA

WHY PAY MORE?

Portable Gas Generator
HONDA EG4000CLAN
PREDATOR
ITEM 59207
VS HONDA
EG4000CLAN*
16 Hours Run Time** 14.8 Hours
4375 Max Starting Watts 4000
3500 Running Watts 3500
Yes 120V & 240V Capable Yes
Yes GFCI Protected Outlets Yes
Yes 12V DC Outlet No
Yes Carbon Monoxide Shutoff Yes
$
499
99
Price
$
1,699
*HONDA EG4000CLAN stated specs.
**@50% load.

Highlights

Powerful
Predator™ 212cc Engine
Extra-Long Run Time
Up to 16 Hours at 50% Load
Recoil Start

Product Features

4375 Watt Gas Powered Portable Generator with CO SECURE Technology
  1. FUEL GAUGE
  2. CO SECURE™ TECHNOLOGY automatically shuts down the generator for safety when harmful levels of carbon monoxide are detected
  3. LOW OIL INDICATOR AND SHUTDOWN
  4. 12V-8A DC OUTLET
  5. GFCI PROTECTED OUTLETS
  6. OUTLET COVERS protect against dust, dirt, and other debris
  7. 120/240V L14-30R TRANSFER SWITCH READY RECEPTACLE
  8. HEAVY DUTY 1 in. STEEL FRAME for protection and easy tie down support
  9. VIBRATION ISOLATORS reduce noise and extend life

Power Outlets

2x
120V 20A
GFCI Protected Duplex Outlets
120V/240V 30A
Twist Lock Outlet
12V 8A
DC Outlet

Ideal Uses

Emergency
Power when you need it most
Home
Backup your small appliances,
lights and more
Jobsite
Power your jobsite tools anywhere
Event Management
Supply power to all
your event equipment

What Can You Power?

4375 Watt Starting / 3500 Watt Running
Air Compressor
1200W
Corded Power Tool
1200W
Small Air Conditioner
1000W
Mini Fridge
150W
LED Lights
50W
SKU(s)
59207
Brand
PREDATOR
Max Running Watts
3500
Output Voltage (volts)
120/240 VAC, 12 VDC
Accessories Included
spark plug wrench and screwdriver
Application
emergencies, jobsites, food trucks, and outdoor recreation
Certification
EPA III
Engine Displacement (cc)
212cc
Fuel Type
87+ Octane Unleaded Gasoline
Horsepower
6.5
Low Oil Shutdown
Yes
Product Height
19-1/4 in.
Product Length
23-1/3 in.
Product Weight
105 lb.
Product Width
18-2/3 in.
Shipping Weight
111.32 lb.
Start Type
Recoil
Max Starting Watts
4375
Run Time
16 hours @ 50%
Sound Rating (dB)
72.5 dB(A)
CA Residents
Warning - Prop 65 Info
Note: Specifications are approximate and subject to change

Be The First

This product has not yet been reviewed

Product Support

These Frequently Asked Questions are a supplement to the Owner's Manual and Safety Instructions. Please review the Owner's Manual for safety warnings and precautions, and assembly, operating, inspection, maintenance, and cleaning procedures.
It depends on how many devices you want to power and their power needs. For more details, see our Generator Selector
  • Perform preventative maintenance, disconnect all electrical plugs, then fill with proper fuel mixture. If the generator engine is in an environment below room temperature (78 F+), move the choke to START (leave choke at RUN if in room temperature or above, or if the engine was recently running and is still warm), and open fuel valve (underneath the fuel tank).
  • Set the Start Switch to ON and then pull the Starter rope until there is some resistance. Let the rope retract and then pull the rope quickly. Repeat rope pulling process as necessary until the engine Starts.
  • After the engine runs for 60 seconds, slowly move the choke to RUN (if at START), then plug in your devices
If your generator is running, however you notice some issues such as (but not limited to) the RPM going up-and-down or the engine making revving noises, there are maintenance tasks you can perform. Confirm all parts of the generator (see manual for components / controls detail) are clean and in good working order, paying special attention to the carburetor and throttle / governor linkage (connected to the carburetor). Clean any debris from the governor spring, air intake and cooling areas. If the unit has been stored with fuel but without a fuel stabilizer, the carburetor may need to be cleaned. Ensure the generator has fresh fuel in the fuel tank and that the spark plug is in good condition. After the engine has started and warmed up, make sure the choke is off (at RUN). If problems persist, call our generator customer service at 888-866-5797.
Generators with a carbon monoxide (CO) sensor can shut down the generator if carbon monoxide accumulates. Always ensure you are running the generator outside and away from enclosed spaces, also be sure the exhaust is not pointed into the wind; using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide, a poison you cannot see or smell. NEVER use inside a home or garage, EVEN IF doors and windows are open. The carbon monoxide sensor is an additional layer of protection only. Do not use the generator in any area or situation that will allow carbon monoxide to accumulate (e.g., enclosed, poorly circulated areas). See manual for further details.

Some generators will shut down if the oil level is low because they are equipped with a low oil level shutdown mechanism to prevent damage. Check the oil level and if it is low, change and refill with fresh oil according to the owner’s manual.

Another cause of a portable generator shutting down may be that it is overloaded. Most devices have a power rating on them indicating how many amps they will draw. Add up the number of amps for all devices you are trying to power, and make sure this number does not exceed the maximum amps the generator can provide. See product manual for further details.
If you plan to store your generator for a few months, you should add a fuel stabilizer to fresh gasoline in the fuel tank. Be sure to turn off the fuel supply at the fuel tank and drain any fuel from the carburetor (see manual for further details). It is a good idea to take care of any upcoming maintenance items, such as oil change, air filter cleaning and spark plug check/replacement. If you think your generator might be in storage for more than a few months, it is advisable to drain the fuel from the fuel tank as well.
Generally, operating a generator at an altitude over 3,000 feet requires installation of a high-altitude kit. A high-altitude kit changes the amount of fuel delivered to the engine to maintain the optimal air/fuel ratio. Operating a generator at high altitude without a high-altitude kit installed may make it difficult to start the generator. The generator may also run roughly, not start high-powered loads, or cause the spark plug and/or spark arrestor not to function properly, requiring more frequent maintenance or replacement. If the generator that you purchased from Harbor Freight did not come with a high-altitude kit, Harbor Freight offers it as a service part. Please call 1-800-444-3353 for assistance.

Installation of a high-altitude kit involves modification of the generator’s fuel system and should be performed by a qualified mechanic. Improper installation of a high-altitude kit can lead to fuel leakage and present a fire hazard. Use only Harbor Freight-approved high-altitude kits for generators sold by Harbor Freight.

Replacement Parts in Stock (PDF)

Call to Order